Previous revision
wear_upgrade_or_update [2013/02/19 14:05]
rcastro
wear_upgrade_or_update [2019/01/03 16:14] (current)
swind created
Line 3: Line 3:
 ===== Must Do ===== ===== Must Do =====
  
-First thing to ensure before updating or upgrading WEAR is to synchronize WEAR dataset transactions to MAIN dataset. This can be done by performing update on WEAR system ​and check on the MAIN system if transactions ​are replicated. Once this is completed performing upgrade or update to both systems can took place.\\+First thing to ensure before updating or upgrading WEAR is to synchronize WEAR dataset transactions to MAIN dataset. This can be done by performing ​the update ​in S5Poll ​on the WEAR Remote computer(s) ​and on the MAIN computer, then check to verify that transactions ​have replicated. Once this is completedperforming ​the upgrade or update to both systems can take place.\\
  
 ===== Difference between Upgrade and Update ===== ===== Difference between Upgrade and Update =====
-To avoid confusion we need to understand ​what is the difference between update and upgrade ​terminologies. \\+To avoid confusion we need to understand the difference between ​the terms update and upgrade. \\
  
-Upgrade process ​is a type of update ​where the application version ​is change ​from 1 major release to another, best example is from version 5.42.0.195 to 6.0.0.132 ​and this require ​data conversion. On the other hand update is only applying a patch on the same version ​series, best example is from version 6.0.0.124 to 6.0.0.132, ​also from 6.0.50.40 to 6.0.50.50 ​and this does not require data conversion. \\+An upgrade ​is where the application version ​has changed ​from 1 major release to another. An example ​of this is when the version ​number has changed from 5.42.0.195 to 6.0.0.132. This upgrade requires System Five to perform a data conversion. ​\\ 
 +On the other hand, an update is only applying a patch to the same version. An example ​of this is when the version ​number has changed ​ from 6.0.0.124 to 6.0.0.132. or another example, from 6.0.50.40 to 6.0.50.50. These would not require ​data conversion. \\
  
 ===== Updating WEAR  ===== ===== Updating WEAR  =====
-Both systemsWEAR and MAIN can be updated in any order mannerMain system can be updated first and vice versa, synchronizing transactions ​is not suggested while version ​of system five between 2 systems is not the sameThey must be updated ​to the same version before performing synchronization.\\+In an update scenarioyou should run a couple update cycles before you update the version. That way there won'​t ​be any outstanding invoices or data sitting on the FTPAny data or batches that are there will be empty batches. Once that is done, you can update the version ​using the FTP Updater within System Five in both the Main and Remote datasetsUsually the Main dataset would be updated ​first, then the remotes. Never attempt to synchronize transactions between two **different** versions of System Five.\\
  
 [[http://​wiki.wws5.com/​doku.php?​id=faq:​updating_system_five&​s=system%205%20update|Click Here for System Five Update Tutorial]]\\ [[http://​wiki.wws5.com/​doku.php?​id=faq:​updating_system_five&​s=system%205%20update|Click Here for System Five Update Tutorial]]\\
Line 19: Line 20:
 ===== Upgrading WEAR ===== ===== Upgrading WEAR =====
  
-Upgrading WEAR from 1 major version to another will take a different ​way to complete it. As stated above this will require data conversion. After upgrading the application version on the MAIN system,it is followed by data conversion. Once this process is completed, the WEAR dataset ​should ​be recreated ​base on newly upgraded dataset ​from the MAIN system.\\+Upgrading WEAR from 1 major version to another will require ​a different ​method. As stated above this will require ​data conversion. After upgrading the application version on the MAIN system, it is followed by data conversion. Once this process is completed, the WEAR dataset ​**must** ​be recreated ​from the newly upgraded ​Main dataset.\\
  
  ​[[http://​wiki.wws5.com/​doku.php?​id=wear_location_recreation|Click here for WEAR dataset recreation tutorial]]  ​[[http://​wiki.wws5.com/​doku.php?​id=wear_location_recreation|Click here for WEAR dataset recreation tutorial]]
  
-After completing ​the recreation wizard, the recreated ​WEAR dataset setting ​in inside ​the MAIN Dataset folder, it needs to be copied to WEAR computer, replaced ​the old WEAR dataset. ​Regarding ​the new major version, a new package should be installed on WEAR computer.(Installer can be downloaded through mywindward website - customer credentials needed). As required ​the WEAR system should have the same version as the MAIN system. +After creating ​the remote ​WEAR datasets from S5poll ​in the man computer, it needs to be copied to WEAR computer. Rename ​the old WEAR dataset ​in case it is needed as a reference laterCopy the new WEAR dataset to the remote ​computer. ​You will also need to download ​the installer for the new version, ​or copy the bin folder ​from the Main computer ​and paste it into the bin folder ​on the remote ​computer. ​The new WEAR Remote **must** have the same version as the MAIN computer.
- +
-Note: If its not possible to install ​the new version ​package on WEAR computerfollowing ​the step for System Five Update Tutorial will work, provided after completing this, its not allowed to log in to WEAR system until its dataset is recreated ​from the main and old WEAR dataset is replaced ​on WEAR computer. ​Old WEAR dataset can be deleted and place the newly recreated Dataset to the same path/​directory. After making sure that both systems are running on the same major version, synchronization process can took place again +
- +
- +
- +
- +
- +
- +
- +
- +
- +
- +
- +
  
 +Note: If its not possible to install the new version package on WEAR computer, following the steps for the System Five Update Tutorial will work, provided you don't log in to the WEAR Remote until its dataset is recreated from the Main and the old WEAR dataset is replaced on WEAR computer. After making sure that both systems are running on the same major version, the synchronization process can take place again. ​
  
  
 +-------------------------------------
 +Updated by Steve Wind January 3 2019
wear_upgrade_or_update.1361311553.txt.gz · Last modified: 2013/02/19 14:05 by rcastro