User Tools

Site Tools


isc250_configuration

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
isc250_configuration [2018/11/09 11:35 (6 years ago)] swindisc250_configuration [2018/11/13 11:30 (6 years ago)] swind
Line 4: Line 4:
 [[http://wws5.com/|{{http://wws5.com/images/topxxxgif-ani.gif  |Windward Software}}]] [[http://wws5.com/|{{http://wws5.com/images/topxxxgif-ani.gif  |Windward Software}}]]
  
-====== Configuration ======+====== SETUP / CONFIGURATION ======
  
 {{::isc250.jpg?200|}} {{::isc250.jpg?200|}}
Line 10: Line 10:
 ====== Configuration Over Terminal Services ====== ====== Configuration Over Terminal Services ======
  
-Recommended setup is using TCPIP +===== Recommended setup is using TCPIP if supported by the payment processor =====
  
 This is the simplest method as well because it doesn't rely on port forwarding or Remote POS Device Manager. This is the simplest method as well because it doesn't rely on port forwarding or Remote POS Device Manager.
Line 18: Line 18:
 https://www.datacapsystems.com/support-articles/how-to-change-pin-pad-interface-settings https://www.datacapsystems.com/support-articles/how-to-change-pin-pad-interface-settings
  
-once configured, Set the pin pad type to the ISC 250 and if supported by the payment processor you can set the IP Address in the setup wizard.+Once configured, Set the pin pad type to the ISC 250 and if supported by the payment processor you can set the IP Address in the setup wizard.
  
 Even though you will not be using a COM port to communicate with the pin pad, the DSI Client software requires one to be selected. If you do not select one you will get an error saying "Incomplete Transaction" "COM port not found in XML". Any valid COM Port can be selected. Even though you will not be using a COM port to communicate with the pin pad, the DSI Client software requires one to be selected. If you do not select one you will get an error saying "Incomplete Transaction" "COM port not found in XML". Any valid COM Port can be selected.
  
  
 +===== When TCPIP isn't supported by Payment processor =====
 +
 +Recommendation is to use the Remote POS Device Manager. This is what it was designed for.
 +
 +http://wiki.wws5.com/doku.php?id=remote_pos_device_manager
 +
 +
 +Don't use port forwarding or COM Port redirection. This is highly problematic, especially for US Payment Processors.
  
    
isc250_configuration.txt · Last modified: 2021/05/11 12:02 (3 years ago) by tanya