faq:zebra_or_eltron_labels_skipping
Differences
This shows you the differences between two versions of the page.
Next revision | Previous revision | ||
faq:zebra_or_eltron_labels_skipping [2008/01/15 14:22 (17 years ago)] – created bob | faq:zebra_or_eltron_labels_skipping [2008/12/03 11:56 (16 years ago)] (current) – andrew | ||
---|---|---|---|
Line 5: | Line 5: | ||
{{faq: | {{faq: | ||
+ | |||
+ | |||
+ | ===== Additional method to manually force the printer to sense the gap ===== | ||
+ | |||
+ | These procedures are to be run when the Zebra printer fails to sense the gap in the labels. | ||
+ | |||
+ | Use only the labels provided by [[http:// | ||
+ | |||
+ | Turn off the printer using the rear power switch. While holding the red light button down, turn the printer power switch back on. Release the depressed red button as soon as the power comes on. The printer will perform a calibration and the red button should change to a green glow. | ||
+ | |||
+ | There is a big distinction between the Zebra printer and Z Designer. Make sure you're using the correct driver and printer. | ||
+ | |||
+ | |||
+ | |||
+ |
faq/zebra_or_eltron_labels_skipping.txt · Last modified: 2008/12/03 11:56 (16 years ago) by andrew